AH Motion Controller – Motion Control Instructions Manual MC_VelocityControl _3 Before using MC_VelocityControl instruction, it is required to confirm if the below object data is supported, and use ECAT Builder in ISPSoft to set the below data in the settings of PDO communications. Target velocity (60FF hex) Modes of operation (6060 hex) Modes of operation display (6061 hex) If one of the above required object data is not set, an error will occur to indicate the problem of missing process data object setting. Inputs 3-88 FB/FC Description FB MC MoveVelocity performs velocity control on an axis in the velocity mode with a specified behavior and _ an average velocity.
Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Continuous Update Continuously updates Velocity BOOL True/False (False) When Active shifts to when Continuousupdate is True and it will update True continuously. Velocity Target velocity. (Unit: user unit/s) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Acceleration Acceleration rate. (Unit: user unit/s2) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Deceleration Deceleration rate. (Unit:
user unit/s2) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Jerk Jerk value. (Unit: user unit/s3) LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False.