Delta Electronics AH — 1.1.1 Fundamentals of Motion Control Instructions

AH Motion Controller – Motion Control Instructions Manual _1  When a DFB_ Instruction is Followed by a BufferMode Instruction (MC_) DFB_ instructions do not have the BufferMode input. Therefore, care should be taken when an on-going motion driven by a DFB_ instruction (e.g. DFB_TrSeg1) is followed by a buffer-mode instruction (e.g. MC_MoveVelocity) following MC_ instruction will report an error. during axis motion status.

When the MC_ instruction is executed, the DFB_ instruction will be aborted, and the  Structures Applicable for Motion Control In PLCopen technical standard, the information and parameters required for configuring motion control on axis are defined in a Structure, which is a kind of the DUT(data type unit) provided by the ISPSoft software. A Structure is a data type applicable to group the data elements together, which is easier for users to specify proper parameters For AH Motion CPUs, the applicable Structure is AXIS_REF as below. *Note : refer to the 2.2.1 Parameters for Motion Axes:

Structure of this manual for the list of parameters grouped in the Structure AXIS_REF which is supported by AH Motion CPU. 1-4 Buffer Mode Function 0: Aborting Aborts the ongoing motion. The next instruction takes effect immediately 1: Buffered Automatically executes the next instruction after the ongoing motion is completed. 2: BlendingLow Takes the lower target velocity as the transit velocity between the current instruction and the buffered instruction. (The transit velocity is the velocity that the current instruction uses as the transit point.) 3: BlendingPrevious Takes the target velocity of the current instruction as the transit velocity. 4:

BlendingNext Takes the target velocity of the buffered instruction as the transit velocity. 5: BlendingHigh Takes the higher target velocity as the transit velocity between the current instruction and the buffered instruction. Structures Definition PLCopen Motion Control FBs AXIS REF* _ Applicable for MC / DFB _ _ function blocks Information and parameters required for configuring axis motion is grouped in this Structure. AXES GROUP REF _ _ N/A Information and parameters required for configuring axes group motion is included in this Structure.

TRIGGER REF _ MC TouchProbe _ MC AbortTrigger _ Information on trigger inputs  Specifications of the trigger  Trigger activation patterns (rising-edge, falling edge, and etc.) INPUT REF _ N/A Information relating to the inputs. Virtual data could be included. OUTPUT REF _ N/A Information relating to physical outputs.