Delta Electronics AH — MC_SetTorqueLimit

AH Motion Controller – Motion Control Instructions Manual MC_SetTorqueLimit _3 Before using MC_SetTorqueLimit instruction, it is required to confirm if the below object data is supported.  Positive torque limit (60E0 hex)  Negative torque limit (60E1 hex)  Inputs 3-104 FB/FC Description FB MC SetTorqueLimit instruction limits the torque output from the servo drive via the torque limit function of _ the servo drive. Name Function Data type Setting value (Default value) Timing for updating Enable The axis is ready to be operated when Enable is True, and not ready when Enable is False. BOOL True/False (False) - PositiveEnable Enables the limit of positive torque when PositiveEnable is True.

Valid only when Enable is True. BOOL True/False (False) Continuously updates value during busy state. PositiveValue Sets the limit of positive torque (Unit: refer to 60E0 hex in the object dictionary) LREAL Refer to 60E0 hex in the object dictionary (0) Continuously updates value during busy state. NegativeEnable Enables the limit of negative torque when NegativeEnable is True. Valid only when Enable is True. BOOL True/False (False) Continuously updates value during busy state. NagativeValue Sets the limit of negative torque (Unit: refer to 60E1 hex in the object dictionary) LREAL Refer to 60E1 hex in the object dictionary (0) Continuously updates value during busy state.