Delta Electronics AH — MC_ReadActualPosition

AH Motion Controller – Motion Control Instructions Manual  Timing Diagram _3  In-Outs *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32.  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of “Errorstop”, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. - Information regarding error codes and indicators and the associated troubleshooting information are attached as Appendices for a quick reference. For the complete troubleshooting of the system, refer to AH Motion Controller – Operation Manual .

 Supported Products - AH Motion Controller CPU: AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-122 Busy  When Enable shifts to True  When Enable shifts to False.  When Error shifts to True. Error/ErrorID  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Enable shifts from True to False. (Error code is cleared) Position Continuously updates value when Valid is True. Continuously updates value when Valid is True. Name Function Data type Setting value Timing for updating (Default value) Axis Motion axis number WORD K1~Kn* (0) When Enable shifts to True.