Chapter 3 Motion Control Instructions Motion diagram: Velocity 300 Time Time 3_ M45(DiscreteMotion) - When MC_ReadStatus is enabled (M3=True), M41 ( Disabled ) change to True, indicating the axis is not yet active. - When MC_Power is enabled (M1 = True), M44 ( Standstill ) changes to True, and M41 ( Disabled ) changes to False. - When MC_MoveRelative is executed (M2=True), the axis starts to move from current position to the designated target position. M45 ( DiscreteMotion ) change to True and M44 ( Standstill ) changes to False. - When the axis reaches the specified target position, M20 ( Done ) and M44 ( Standstill ) change to True, and M45 (DiscreteMotion) changes to False.
- When MC_Power is disabled (M1 = False), M41 ( Disabled ) changes to True, and M44 ( Standstill ) changes to False. - When MC_ReadStatus is disabled (M3 = False), M41 ( Disabled ) remains unchanged. 3-131 MC Power _ M1(Enable) M10(Status) M11(Busy ) M12(Active) MC MoveRelative _ M2(Execute) M20(Done) M21(Busy) M22(Active) M23(CommandAborted) M24(Error)