Delta Electronics AH — MC_ReadMotionState

Chapter 3 Motion Control Instructions MC_ReadMotionState 3_ The output Valid is True when the output s relating the axis motion status are valid. If Enable is reset, the data loses its validity, and all outputs are reset. In this case, to update new motion state requires enabling this instruction again.  Inputs *Note: Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations.  Outputs 3-133 FB/FC Description FB MC ReadMotionState reports details of the axis status relating the on-going motion behavior. _ Name Function Data type Setting value Timing for updating (Default value) Enable Executes the instruction when Enable changes to True.

BOOL True/False (False) - Source Selects the source of the relating data: Commanded Value: The value commanded by the controller. Actual Value: The actual value on the motion axis. * eMC SOURCE _ 1: mcCommandedValue 2: mcActualValue (0) When Enable is rising-edge triggered and Busy is False. Name Function Data type Output range (Default value) Valid True when the axis states at the output is available. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to DWORD 16#0~16#FFFFFFFF (0)