Delta Electronics AH — MC_TouchProbe

Chapter 3 Motion Control Instructions to be activated immediately after WindowOnly shifts to True and until the touch probe operation is actually 2. If the window mask is too small, the touch probe operation is not possble. The effective range for the window activated. mask depends on EtherCAT communications and the performance of encoder input or the servo drive.  Window Mask Settings - You can observe the results of different window mask settings when the instruction is used for rotary/modulo axes as below. The difference is resulted from the set values between FisrPosition and LastPosition .

3_  TriggerInput Settings - Drive Mode The captured position in Drive Mode is more accurate than it is in Controller Mode since the Drive Mode references the actual position of the servo drive for the capture operation. - Controller Mode refresh dalay) of the controller. The captured position in Controller Mode is less accurate than it is in Drive Mode due to the scan time (I/O 1. In Controller Mode, you can declare a BOOL variable to be the trigger input signal. 2. The BOOL variable funcitons as trigger input signal can be specified for TriggerSignal . 3-147