Chapter 3 Motion Control Instructions MC_AbortTrigger Inputs 3_ Outputs Outputs Update Timing 3-149 FB/FC Description FB MC AbortTrigger aborts the instruction MC TouchProbe which are intended to capture trigger events _ _ Name Function Data type Setting value Timing for updating (Default value) Execute Executes the instruction and aborts trigger events. BOOL True/False (False) - Name Function Data type Output range (Default value) Done True when trigger event is aborted BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs BOOL True/False (False) ErrorID Indicates the error code when the error occurs.
Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done When the capture operation is stopped. When the instruction is executed on a capture operation which is not in execution. When Execute shifts from True to False. If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy When Execute shifts to True and the instruction is executed. When Done shifts to True. When Error shifts to True.
Error/ErrorID When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded) When Execute shifts from True to False. (Error code is cleared)