Delta Electronics AH — MC_CamIn

AH Motion Controller – Motion Control Instructions Manual - If the stroke position of the slave axis is the same at the start and end points of the cam table when True (periodic) is set, the cam operates as a reciprocal cam. If the stroke position of the slave axis differs at the start point and end point, the cam operates as a feeding cam. In the following chart, the horizontal axis indicates the master axis and the vertical axis indicates the slave axis. Rotary/reciprocal Cam Operation _3 Feeding Cam Operation  MasterOffset/MasterScaling/SlaveOffset/Slavescaling The cam relationship between the master axis and slave axis is preplanned.

But as the cam motion is executed, the position offset or scaling based on the preplanned cam relationship can be performed through setting the Offset and Scaling parameters. For example, there are various sizes for the same product which is processed. Just one cam relationship need be planned and then changing the values of Offset and Scaling fits the processing of products of different sizes. The position offset and scaling of the master axis and slave axis determine the actually executed cam relationship. The effect is described in the following example. The planned cam relationship is shown as the figure below. 3-164