Chapter 3 Motion Control Instructions StartMode =1 (RampIn_Shortest) - The slave axis will move to the synchronization point by taking the shortest way at the set parameters. - The execution of the engagement action, the slave axis moves toward the position for synchronization by taking the shortest way. (using the shortest distance In Ramp In Positive or Ramp In Negative; if the distances of Ramp In Positive and Ramp In Negative are the same, use the vaule in Ramp In Positive) - The following figure shows that C1 is a planned cam curve and C2 is an actually performed cam curve.
Point A is the (master, slave) position triggering the MC_CamIn instruction and point B is the synchronization point for master and slave axes. - At the moment, the motion of the slave axis is affected by the Velocity, Acceleration Deceleration and Jerk parameters. 3_ 3-169 Ramp In Postive The slave axis moves 297 units from the start point A to the synchronization point B (297 = (360-227) + (164-0)) in the positive direction. Ramp In Negative The slave axis negatively moves 63 units from the start point A to the synchronization point B (63=227-164). The shortest distance is Ramp In Negative (63).