Delta Electronics AH — MC_CamIn

Chapter 3 Motion Control Instructions  The impact of other instructions on cam operation  MC_CamOut The MC_CamOut instruction can be used to end the cam operation which is being carried out.  MC_SetPosition The MC_SetPosition instruction has no impact on the being executed motion instructions. Thus, during affect the cam operation. If the cam operation is triggered after the MC_SetPosition instruction is cam operation, the execution of MC_SetPosition instruction for the master axis and slave axis will not executed, the cam will be affected by the axis position change which is incurred by using the MC_SetPosition instruction.

 MC_Stop and MC_Halt As the MC_Stop and MC_Halt instructions are executed on the slave axis, the MC_CamIn instruction is aborted, the cam relationship is disconnected and the slave axis decelerates till it stops.  MC_Home 3_ The MC_Home instruction cannot be executed on the slave axis but the master axis. As the MC_Home instruction is executed on the master axis, the master axis position may have a great change in a very short time, which may cause the vibration of the slave axis. Therefore, the MC_Home instruction is recommended to execute after the synchronous relationship between the two axes is disconnected.

 BufferMode BufferMode determines the behavior to combine the axis motions for this instruction and the previous instruction. When the instruction is executed; - The selected buffer mode is valid if the previous instruction is executing. - The selected buffer mode is invalid if the axis is in Standstill state. The following table lists the available buffer mode settings of MC_CamIn. The following table lists the buffer effects of MC_ Camin. For more information of buffer mode, refer to AH Motion Controller – Operation Manual . 3-171 Buffer Mode Function 0: mcAborting Aborts the ongoing motion. The next instruction takes effect immediately 1:

mcBuffered Automatically executes the next instruction after the ongoing motion is completed. Instruction Can be specified as a buffered instruction Can be followed by a buffered instruction Relevant signal to activate the next buffered instruction MC CamIn _ YES YES EndOfProfile