Chapter 3 Motion Control Instructions The impact of other instructions on cam operation MC_CamOut The MC_CamOut instruction can be used to end the cam operation which is being carried out. MC_SetPosition The MC_SetPosition instruction has no impact on the being executed motion instructions. Thus, during affect the cam operation. If the cam operation is triggered after the MC_SetPosition instruction is cam operation, the execution of MC_SetPosition instruction for the master axis and slave axis will not executed, the cam will be affected by the axis position change which is incurred by using the MC_SetPosition instruction.
MC_Stop and MC_Halt As the MC_Stop and MC_Halt instructions are executed on the slave axis, the MC_CamIn instruction is aborted, the cam relationship is disconnected and the slave axis decelerates till it stops. MC_Home 3_ The MC_Home instruction cannot be executed on the slave axis but the master axis. As the MC_Home instruction is executed on the master axis, the master axis position may have a great change in a very short time, which may cause the vibration of the slave axis. Therefore, the MC_Home instruction is recommended to execute after the synchronous relationship between the two axes is disconnected.
BufferMode BufferMode determines the behavior to combine the axis motions for this instruction and the previous instruction. When the instruction is executed; - The selected buffer mode is valid if the previous instruction is executing. - The selected buffer mode is invalid if the axis is in Standstill state. The following table lists the available buffer mode settings of MC_CamIn. The following table lists the buffer effects of MC_ Camin. For more information of buffer mode, refer to AH Motion Controller – Operation Manual . 3-171 Buffer Mode Function 0: mcAborting Aborts the ongoing motion. The next instruction takes effect immediately 1:
mcBuffered Automatically executes the next instruction after the ongoing motion is completed. Instruction Can be specified as a buffered instruction Can be followed by a buffered instruction Relevant signal to activate the next buffered instruction MC CamIn _ YES YES EndOfProfile