Chapter 3 Motion Control Instructions Actual master and slave position corresponding to the end point of cam curve: Actual master position: To perform displacement on the cam curve, master axis needs to move 360 from point (0, 0) to complete one cam cycle. Since master scaling is 2, master axis needs to move 720 from current position in actual displacement to complete one cycle, i.e. the actual master axis position of the end point: 30+720= 750 . Actual slave position: In the cam curve, slave axis moves 360 from point (0, 0) to reach the maximum value. Since slave scaling is 2, slave axis needs to move 720 positively from current position so as to reach the maximum value, i.e. 180+720=900.
In the cam curve, slave axis moves 360 from the maximum value to the end point position: 0. Since slave scaling is 2, slave axis needs to move 720 negatively from the maximum value to reach the end point, i.e. 900-720= 180 . To sum up, the actual end point position is (750, 180). Supported Products 3_ − AH Motion Controller CPU: AHxxEMC-5A − AH series motion control modules: AHxxEMC-5A 3-175