Delta Electronics AH — MC_GearOut

AH Motion Controller – Motion Control Instructions Manual MC_GearOut disconnected and become available for executing other motion instructions. After the execution of MC_GearOut is finished, the disengaged slave axis will keep the velocity where the gear relation is _3  Inputs  Outputs  Outputs Update Timing 3-188 FB/FC Description FB MC GearOut disconnects the gear relation (velocity) between master and slave axis. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Name Function Data type Output range (Default value) Done True when the gear disconnection is completed.

BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) CommandAb orted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done  When the gear disconnection is completed.  When Execute shifts from True to False.  If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy  When Execute changes to True.  When Done shifts to True.