AH Motion Controller – Motion Control Instructions Manual MC_GearOut disconnected and become available for executing other motion instructions. After the execution of MC_GearOut is finished, the disengaged slave axis will keep the velocity where the gear relation is _3 Inputs Outputs Outputs Update Timing 3-188 FB/FC Description FB MC GearOut disconnects the gear relation (velocity) between master and slave axis. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - Name Function Data type Output range (Default value) Done True when the gear disconnection is completed.
BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) CommandAb orted True when the instruction is aborted. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 16#0~16#FFFFFFFF (0) Name Timing for shifting to True Timing for shifting to False Done When the gear disconnection is completed. When Execute shifts from True to False. If Execute is False and Done shifts to True, it will be True for only one period and immediately shift to False. Busy When Execute changes to True. When Done shifts to True.