Delta Electronics AH — MC_GearOut

AH Motion Controller – Motion Control Instructions Manual  Function The MC_GearOut instruction ends gear synchronization of the slave axis. After the gear relationship is disconnected, the slave axis will keep moving at the speed where the gear relationship is disconnected.

The axis will be in ContinuousMotion (it has nothing to do with the axis velocity) - The sequence for execution of the instructions related to electronic gear MC_Power Rebuilds the gear relation after modifying the parameters while gear is running MC_GearIn Builds gear relation _3 Disconnects gear relation Rebuilds gear relation after MC_GearOut disconnecting the gear relation  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of “Errorstop”, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem.

- Information regarding error codes and indicators are attached as Appendices for a quick reference. The detailed troubleshooting procedures are explained in AH Motion Controller – Operation Manual .  Programming Example The following example describes the corresponding motion state throughout the gear operation via gear-related instructions. 3-190