Delta Electronics AH — DFB_InputPolarity

Chapter 3 Motion Control Instructions  Outputs Update Timing 3_ 3-219 Name Function Data type Output range (Default value) Nor X1 04 _ _ State of the input terminal BOOL True/False (False) Nor X1 05 _ _ State of the input terminal BOOL True/False (False) Name Timing for shifting to True Timing for shifting to False Vaild  When the polarity setting is completed; one scan cycle after Enable shifts to True.  When Enable shifts to False. Busy  When Enable shifts to True.  When Enable shifts to False. Pgo X0 00 _ _  When the output is ON and the external signal is OFF during operation.  When the output is OFF and the external signal is ON during operation.  When Enable shifts to False.

 When the output is ON and the external signal is ON during operation.  When the output is OFF and the external signal is OFF during operation. Pg1 X0 01 _ _  When the output is ON and the external signal is OFF during operation.  When the output is OFF and the external signal is ON during operation.  When Enable shifts to False.  When the output is ON and the external signal is ON during operation.  When the output is OFF and the external signal is OFF during operation. Pg2 X0 02 _ _  When the output is ON and the external signal is OFF during operation.  When the output is OFF and the external signal is ON during operation.  When Enable shifts to False.

 When the output is ON and the external signal is ON during operation.  When the output is OFF and the external signal is OFF during operation. Pg3 X0 03 _ _  When the output is ON and the external signal is OFF during operation.  When the output is OFF and the external signal is ON during operation.  When Enable shifts to False.  When the output is ON and the external signal is ON during operation.  When the output is OFF and the external signal is OFF during operation. mpgA X0 08 _ _  When the output is ON and the external signal is OFF during operation.  When the output is OFF and the external signal is ON during operation.  When Enable shifts to False.

 When the output is ON and the external signal is ON during operation.  When the output is OFF and the external signal is OFF during operation. mpgB X0 09 _ _  When the output is ON and the external signal is OFF during operation.  When the output is OFF and the external signal is ON during operation.  When Enable shifts to False.  When the output is ON and the external signal is ON during operation.  When the output is OFF and the external signal is OFF during operation. Dog4 X0 10 _ _  When the output is ON and the external signal is OFF during operation.  When the output is OFF and the external  When Enable shifts to False.

 When the output is ON and the external signal is ON during operation.