Delta Electronics AH — DFB_CamCurveUpdate2

AH Motion Controller – Motion Control Instructions Manual DFB_CamCurveUpdate2 - When the cam is in operation, the cam profile modified by DFB_CamCurve2 will not be executed immediately, and the update requires to be triggered by DFB_CamCurveUpdate2. - When DFB_CamCurveUpdate2 is triggered, the update will be valid in the next cycle. _3  Inputs  Outputs  Outputs Update Timing 3-232 FB/FC Description FB DFB CamCurveUpdate2 updates the cam operation with the modified cam profile in the next cycle. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction to update the cam profile.

BOOL True/False (False) - UpdateImme diately Update cam profile immediately in this cycle. BOOL True/False When Execute shifts to True and Busy is Fasle. (False) Name Function Data type Output range (Default value) Done True when the cam curve is updated. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions. DWORD 0x0000, 0x3100, 0x3101, 0x3102 (0) Name Timing for changing to True Timing for changing to False Done  When the cam curve is updated.  When the motion stops.  When Error shifts to True.

Busy  When the instruction is executed  When Done shifts to True.  When Error shifts to True. Error/ErrorID  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Execute shifts from True to False.  (Error code is cleared)