Chapter 3 Motion Control Instructions Updates the cam curve Takes effect at the next cycle. Cam curve no. 9 becomes valid. One Cycle 3_ 1. Set M10( Execute ) to True to establish the specified cam curve no.1 (DFB_CamCurve2). Set M50( Execute ) to True obtained at CAMCurveNow will indicate 1 (DFB_CamCurveUpdateState). to update the cam curve(DFB_CamCurveupdate2). In this case, if SM400( Enable ) is True, the current cam curve 2. Set M70 to True to enable the cam operation. 3. Set M40 to True to drive the master axis to move at 10,000pps. 4. Reset M10 and modify the value at eCamCurve to cam curve no. 9. 5.
Set M10 to True again to establish the new cam curve, and set M50 to True to update the cam curve. The cam in operation will update its cam curve to cam curve no. 9 at the next cycle. When the cam curve is updated, CAMCurveNow of DFB_CamCurveUpdateState2 will indicate “9”. Supported Products - AH Motion Controller CPU: AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-235