Delta Electronics AH — DFB_GroupRelLinear

Chapter 3 Motion Control Instructions 3_ - When M2( Execute ) changes to True, MC_GroupRelLinear drives the axes to move a relative distance to the target position with linear interpolation. - When the specified relative distances (1000, 2000, 3000, 4000, 5000) are completed, M20(Done) - When M2(Execute) changes to False, M20(Done) changes to False. changes to True, and M21 and M22 change to False. - When the axes completed the specified relative distance(1000, 2000, 3000, 4000, 5000) and then M2 changes to True again, the instruction will be executed again to move another distance (1000, 2000, 3000, 4000, 5000) and reach the position of 3000, 5000,7000, 9000 and 11000.

- When the specified distance is completed, M20(Done) changes to True again.  Supported Products − AH Motion Controller CPU: AHxxEMC-5A − AH series motion control modules: AHxxEMC-5A 3-249