Delta Electronics AH — DFB_GroupAbsCircular

Chapter 3 Motion Control Instructions 3_ *Note: 1. Parameters of DirectionCCW : 2. Parameters of IPMode and AuxPosition : 3. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations. 4. TransitionMode can be used to reduce the noise and vibration that may occur during the changes of the interpolation motion. 3-251 Name Function Data type Setting value (Default value) Timing for updating center of the circle.*2 Velocity Interpolation speed (Unit: user unit/s) *3 LREAL Positive value (0) When Execute shifts to True and Busy is False. SpiralTurns Specifies the number of spirals in a helix. DWORD 0~65535 When Execute shifts to True and Busy is False.

BufferMode Specifies the buffering behavior of the instruction. eMC BUFF _ ER MODE*3 _ 0: mcAborting 1: mcBuffered 2: mcBlendingLow 3: mcBlendingPrevious 4: mcBlendingNext 5: mcBlendingHigh (0) When Execute shifts to True and Busy is False. TransitionMode Specifies if a round corner should be applied during the transition*2 WORD 0: no effect 1: round corner 2: round corner but ignoring the deceleration time (0) When Execute shifts to True and Busy is False. State Definition False Clockwise True Counterclockwise Input value of IPMode Definition Value 1 of AuxPosition Value 2 of AuxPosition 0 Radius(R) Length of radius(R) N/A 1 Center of circle(I,J) Value of I Value of J