Delta Electronics AH — DFB_GroupRelCircular

Chapter 3 Motion Control Instructions  Outputs Update Timing 3_  Timing Diagram 3-263 Name Timing for shifting to True Timing for shifting to False Done  When the absolute positioning is completed.  When Execute shifts from True to False.  If Execute is False and Done shifts to True, Done will be True for only one period and immediately shift to False. Busy  When Execute changes to True.  When Done shifts to True.  When Error shifts to True.  When Aborted shifts to True. Active  When the motion on the axis is started  When Done shifts to True.  When Error shifts to True  When Aborted shifts to True.

Aborted  When this instruction is aborted by another instruction with the Buffer Mode set to mcAborting.  When this instruction is aborted because of the execution of MC Stop instruction. _  When the instruction is aborted by DFB GroupStop instruction _  When the instruction is aborted by DFB GroupImmediateStop instruction. _  When Execute shifts to False.  If Execute is False and Aborted shifts to True, it will be True for only one period and immediately shift to False. Error(ErrorID)  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Execute shifts from True to False. (Error code is cleared)