Delta Electronics AH — DFB_GroupStop

AH Motion Controller – Motion Control Instructions Manual DFB_GroupStop - The axis group specified by GroupNum will be decelerated to stop or pause. - The group motion can be G-code motion, linear interpolation or circular interpolation. - The axis states will enter Stopping after the execution of DFB_GroupStop. _3 - The axis state Stopping will go till the velocity becomes zero or when Execute shifts to False. When the velocity Standby. becomes zeron, Done shifts to Ture. And when Done is True and Execute shifts to False, the axis state will enter Note: 1.

For more information about the axis states after DFB_GroupStop is executed, refer to 7.4 State Transitions of AH Motion Controller – Operation Manual .  Inputs  Outputs 3-266 FB/FC Description FB DFB GroupStop decelerates the group axes to stop or pause. _ Name Function Data type Setting value (Default value) Timing for updating GroupNum Specifies the number of the axis group. WORD 1~32 When Execute shifts to (0) True and Busy is False. Execute Executes the instruction when Execute changes to True. BOOL True/False (False) - StopMode The axis stops. WORD 0: Stop 1: Pause (0) When Execute shifts to True and Busy is False. When Execute shifts to Fault and Done is True.

Name Function Data type Output range (Default value) Done True when the group motion is stopped. BOOL True/False (False) Busy True when the instruction is executed. BOOL True/False (False) Error True if an error occurs. BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code DWORD 16#0~16#FFFFFFFF (0)