Delta Electronics AH — DFB_ReadGroupStatus

AH Motion Controller – Motion Control Instructions Manual DFB_ReadGroupStatus _3  Inputs  Outputs 3-278 FB/FC Description FB DFB ReadGroupStatus reads the axis numbers in an axis group, and indicates the status of the axis _ group at GroupStatus. Name Function Data type Setting value (Default value) Timing for updating GroupNum Specifies the number of the axis group. WORD 1~16 When Enable shifts to True. (0) Enable Reads the axis numbers and the status of the axis group. BOOL True/False (False) - Name Function Data type Output range (Default value) Valid True when the axis group state at the output is available. BOOL True/False (False) Error True if an error occurs.

BOOL True/False (False) ErrorID Indicates the error code if an error occurs. Refer to Appendices for error code descriptions DWORD 16#0~16#FFFFFFFF (0) AxisNumOrder 1 _ Indicates the axis number for the 1st axis (X-axis ) WORD 0~32(0) AxisNumOrder 2 _ Indicates the axis number for the 2nd axis (Y-axis ) WORD 0~32(0)