Delta Electronics AH — DFB_ReadGroupStatus

AH Motion Controller – Motion Control Instructions Manual  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of “Errorstop”, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. - Information regarding error codes and indicators and the associated troubleshooting information are attached as Appendices for a quick reference. For the complete troubleshooting of the system, refer to AH Motion Controller – Operation Manual .  Programming Example The example uses DFB_ReadGroupStatus to read the axis numbers and the group status when the specified group is enabled. _3 1.

DFB_GroupEnable is required to enable the axis group for executing coordinated motion in 4 axes (axis 1 to axis 4). 2. Set M100 to True to enable the axis group number 1 which uses axis 1 to axis 4. 3. M101( Done )=True indicates the completion of the enabling of axis group number 1. Group state will change from “Disabled” to “Standby”, and the axis state in the group will change from “Standstill” to “Coordinated”. 4. When the axis group is enabled, it can be used for executing coordinated motion or multi-axis interpolation. 5. When the group motion is in operation, you can read the status of axis group number 1 by DFB_ReadGroupStatus . 6.

Set M200 to True to read the axis numbers and the group state at the outputs of DFB_ReadGroupStatus.  Supported Products - AH Motion Controller CPU: AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-280