Delta Electronics AH — DFB_HTmr

Chapter 3 Motion Control Instructions DFB_HTmr - You can specify the high speed timer to be enabled by Channel and the timing mode by TriggerMode. 3_ - To read the timed value during the high speed timer operation, you can monitor the output TimerValue .  Inputs * Note : 1. The setting value of Channel input 3-285 FB/FC Description FB DFB HTmr enables the specified high speed timer channel according to the specified parameters and _ monitors and timed value. Name Function Data type Setting value Timing for updating (Default value) Channel Specifies the timing channel of the high speed timer. WORD 200: DFB AC0 _ 204: DFB AC4 _ 208: DFB AC8 _ 212:

DFB AC12 _ (0) *1 When Enable shifts to True Enable Enables the specified high speed timer when Enable changes to True. BOOL True/False(False) - TriggerMode Timing mode settings*2 Up Down: measuring the interval _ between the rising edge and the falling edge of a pulse. Up Up: measuring the interval _ between the rising edge of a pulse and the rising edge of the following pulse. BOOL mcUp Down: False _ mcUp Up: True _ (False) When Enable shifts to True Channel Setting Terminals value 0 200 X0.0 1 204 X0.1 2 208 X0.2 3 212 X0.3