Chapter 3 Motion Control Instructions 3_ 1. Set M2( OutputMode ) to True and OutputDeivce =0 to specify the output operation of the instruction when the comparison result is True: Set Y0.8=ON. 2. Set M1=ON to enable the comparator of number 0. 3. Set M11=ON to enable the counting on channel 1 . 4. Confirm if Y0.8 is set to True when the count value in D14 is greater or equals to 1000. Supported Products - AH Motion Controller CPU: AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-291