Chapter 3 Motion Control Instructions Outputs Update Timing 3_ Timing Diagram Function MaskValue Refer to the below diagram for the explanation of MaskValue: 1. Specify 500 to MaskValue , and 0 to InitialValue . When Enable is set to True, the initial value wille be the center reference of the mask range, and the mask range will be -500~500. Within the mask range, the Capture will be invalid. 3-299 Name Timing for shifting to True Timing for shifting to False Valid When the values at the outputs are available. When the motion stops. When Enable shifts to False. When Error shifts to True. Busy When the instruction is enabled. When Enable shifts to False.
Error/ErrorID When the specified axis is already in motion. When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded) When Enable shifts from True to False. (Error code is cleared) CapFlag Updates value continuously when Valid is True. Updates value continuously when Valid is True. CapValue Updates value continuously when Valid is True. Updates value continuously when Valid is True. CapValuePrevi ous Updates value continuously when Valid is True. Updates value continuously when Valid is True. Delta Updates value continuously when Valid is True. Updates value continuously when Valid is True.
CapLenBeyon dFlag Updates value continuously when Valid is True. Updates value continuously when Valid is True. CapLenBeyon dCount Updates value continuously when Valid is True. Updates value continuously when Valid is True.