Delta Electronics AH — DFB_SDO_Read

AH Motion Controller – Motion Control Instructions Manual DFB_SDO_Read _3  Inputs 3-314 FB/FC Description FB D DFB SDO Read reads the values of parameters from the specified OD of the EtherCAT Slave via _ _ SDO. Name Function Data type Setting value Timing for updating (Default value) Execute Executes the instruction when Execute changes to True. The value of the specified parameter will then be read. BOOL True/False (False) - SlaveAddress ECAT Slave ID (Refer to manuals of the device that is used as slave) WORD 1~9999 (0) When Execute shifts to True and Busy is False.

ODIndex ECAT Slave ODIndex (Refer to manuals of the device that is used as slave) WORD Refer to manuals of the device that is used as slave (0) When Execute shifts to True and Busy is False. ODSubIndex ECAT Slave ODSubIndex (Refer to manuals of the device that is used as slave) WORD Refer to manuals of the device that is used as slave (0) When Execute shifts to True and Busy is False. DataType Bit lenghth of the data to be written in OD WORD 3: UINT08bits 0: UINT16bits 1: UINT32bits 2: UINT64bits (reserved) 7: SINT08bits 4: SINT16bits 5: SINT32bits 6: SINT64bits (reserved) When Execute shifts to True and Busy is False.