Delta Electronics AH — DFB_SDO_Write

AH Motion Controller – Motion Control Instructions Manual DFB_SDO_Write _3  Inputs 3-318 FB/FC Description FB DFB SDO Write writes the values of parameters into the specified OD of the EtherCAT Slave via SDO. _ _ Name Function Data type Setting value Timing for updating (Default value) Execute Executes the instruction when Execute changes to True. The value of the specified parameter will then be written. BOOL True/False (False) - SlaveAddress ECAT Slave ID (Refer to manuals of the device that is used as slave) WORD 1~9999 (0) When Execute shifts to True and Busy is False.

ODIndex ECAT Slave ODIndex (Refer to manuals of the device that is used as slave) WORD Refer to manuals of the device that is used as slave (0) When Execute shifts to True and Busy is False. ODSubIndex ECAT Slave ODSubIndex (Refer to manuals of the device that is used as slave) WORD Refer to manuals of the device that is used as slave (0) When Execute shifts to True and Busy is False. Data Data to be written in OD LREAL K-2147483648~ K2147483647 (0) When Execute shifts to True and Busy is False. DataType Bit lenghth of the data to be written in OD 3: UINT08bits 0: UINT16bits 1: UINT32bits 2: UINT64bits When Execute shifts to True and Busy is False.