Delta Electronics AH — DFB_SDO_Write

AH Motion Controller – Motion Control Instructions Manual  Timing Diagram  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of Errorstop, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. _3 - Information regarding error codes and indicators and the associated troubleshooting information are attached as Appendices for a quick reference. For the complete troubleshooting of the system, refer to AH Motion Controller – Operation Manual .

 Programming Example The example uses DFB_SDO_Write to write the values of the specified parameters in the slave 1001 (Delta ECAT servo drive). For details of the servo drive parameters and the contents of mapping OD, refer to the relative Delta manuals. 1. If you want to write 128 to the parameter P1-44, specifiy 0x212C to the filed of the Index and 0 to the field of SubIndex and make sure if the type of 0x212C is UDINT in the table of CoE Object-Dictionary in ECAT Builder. The DataType shuld be 1 and then specify a desired retry times to D1 (Retry). 2.