Delta Electronics AH — A.1. Table of Data Type Unit(DUT): Enum

AH Motion Controller – Motion Control Instructions Manual _A1 A-6 Data Type Value Description Applicable Function Block Instruction and its Interface eDFB CAP _ 0: Ch0 1: Ch1 2: Ch2 3: Ch3 4: Ch4 5: Ch5 6: Ch6 7: Ch7 0: channel 0 1: channel 1 2: channel 2 3: channel 3 4: channel 4 5: channel 5 6: channel 6 7: channel 7 DFB Capture/ _ DFB Capture2 _ Interface: Source eDFB CAP TRIG DEV _ _ _ 0: X0p0 1: X0p1 2: X0p2 3: X0p3 8: X0p8 9: X0p9 10: X0p11 11: X0p11 12: X0p12 13: X0p13 14: X0p14 0: trigger by X0.0 signal 1: trigger byX0.1 signal 2: trigger by X0.2 signal 3: trigger by X0.3 signal 8: trigger by X0.8 signal 9: trigger by X0.9 signal 10: trigger by X0.10 signal 11:

trigger by X0.11 signal 12: trigger by X0.12 signal 13: trigger by X0.13 signal 14: trigger by X0.14 signal DFB Capture/ _ DFB Capture2 _ Interface: TriggerDevice eDFB CAP SOURCE _ _ 0: Axis1 1: Axis2 2: Axis3 3: Axis4 4: AC0 5: AC4 6: AC8 7: AC12 8: AC16 0: capture axis 1 1: capture axis 2 2: capture axis 3 3: capture axis 4 4: capture high speed counter 1 5: capture high speed counter 2 6: capture high speed counter 3 7: capture high speed counter 4 8: capture high speed counter 5 DFB Capture/ _ DFB Capture2 _ Interface: Source