Appendix 6. Data Type Unit: Enum A2_ A-51 Error Code Description Corrective action 16#001B Timed interrupt 0 is set incorrectly. Set the CPU parameter in HWCONFIG again, and download the CPU parameter again. 16#001C Timed interrupt 1 is set incorrectly. Set the CPU parameter in HWCONFIG again, and download the CPU parameter again. 16#001D Timed interrupt 2 is set incorrectly. Set the CPU parameter in HWCONFIG again, and download the CPU parameter again. 16#001E Timed interrupt 3 is set incorrectly. Set the CPU parameter in HWCONFIG again, and download the CPU parameter again. 16#001F The watchdog timer is set incorrectly.
Set the CPU parameter in HWCONFIG again, and download the CPU parameter again. 16#0020 The setting of the fixed scan time is incorrect. Set the CPU parameter in HWCONFIG again, and download the CPU parameter again. 16#0021 The setting of the fixed scan time is incorrect. Set the CPU parameter in HWCONFIG again, and download the CPU parameter again. 16#0022 The CPU parameter downloaded to the PLC is incorrect. Download the CPU parameter again. 16#0023 CPU parameters setting error. The state of Y devices when the CPU is set from STOP to RUN is incorrect Adjust the CPU parameters setting in HWCONFIG and download it to PLC again.
16#0026 The Communication Ratio box in the Communication Loading of Scan Time (%) section in the PLC Parameter Setting window is set incorrectly. Reset the CPU or set the CPU to the default settings, and download the program and parameters again. 16#0027 The latching auxiliary relay range which is set is incorrect. Reset the CPU or set the CPU to the default settings, and download the program and parameters again. 16#0028 The latching data register range which is set is incorrect. Reset the CPU or set the CPU to the default settings, and download the program and parameters again. 16#0029 The latching timer range which is set is incorrect.
Reset the CPU or set the CPU to the default settings, and download the program and parameters again.