AH Motion Controller – Motion Control Instructions Manual _2 2-26 FB/FC Name Graphic expression Description FB MC CamOut _ Cam operation is ended for the axis specified with the input parameter. FB MC GearIn _ MC GearIn _ establishes the gear relation (velocity) between master and slave axis. FB MC GearOut _ MC GearOut _ disconnects the gear relation (velocity) between master and slave axis. FB MC PhasingAbsolute _ MC PhasingAbsolute _ shifts the phase of the master axis virtually by a specified absolute phase shift value.