AH Motion Controller – Motion Control Instructions Manual 3.2 PLCopen-based Motion Control Instructions _3 3-10 Categories Name Description Single-axis motion control Instructions Position Control MC Home _ MC Home drives the axis to perform the homing operation. _ MC Stop _ MC Stop decelerates an axis to a stop. _ MC Halt _ MC Halt halts an axis. _ MC MoveAbsolute _ MC MoveAbsolute controls the axis to move to the specified _ absolute target position at a specified behavior. MC MoveRelative _ MC MoveRelative controls the axis to move a specified _ relative distance with a specified behavior.
MC MoveAdditive _ MC MoveAdditive controls the axis to move an additional _ distance at a given speed and acceleration. MC MoveSuperImposed _ MC MoveSuperimposed controls the axis move a relative _ superimposed distance at a specified behavior while the axis is moving. MC HalfSuperimposed _ MC HaltSuperimposed halts all superimposed motions of _ the axis without aborting the previous superimposed motion. Velocity Control MC MoveVelocity _ MC MoveVelocity performs velocity control on an axis in the _ position mode with a specified behavior and an average velocity.
MC VelocityControl _ MC VelocityControl performs velocity control on an axis in _ the velocity mode with a specified behavior and an average velocity. Torque Control MC TorqueControl _ MC TorqueControl controls the torque by using the Torque _ Control Mode of the applied servo drive. Synchronized control MC CamIn _ MC CamIn performs cam operation by engaging the cam. _ MC CamOut _ Cam operation is ended for the axis specified with the input parameter. MC GearIn _ MC GearIn establishes the gear relation (velocity) between _ master and slave axis. MC GearOut _ MC GearOut disconnects the gear relation (velocity) _ between master and slave axis.
MC PhasingAbsolute _ MC PhasingAbsolute shifts the phase of the master axis _ virtually by a specified absolute phase shift value. MC PhasingRelative _ MC PhasingRelative shifts the phase of the master axis _ virtually by a specified relative phase shift value. Administrative MC Power _ MC Power enables or disables the corresponding servo _ axis.