Mitsubishi — 3.9.1 General Specifications

AH500 Hardware Manual *1. If the frequency of input signals received by an input terminal must be 200 kHz, the input terminal must be connected to a 1 kΩ (2 W) resistor in parallel.  AH15PM-5A 3-76 Terminal Description c Response c Maximum input haracteristi Curren t Voltage  Y0.8 and Y0.9 are for axis 5. Y0.10 and Y0.11 are for axis 6. Y0.8 is the A-phase output for axis 5, and Y0.10 is the A-phase output for axis 6. Y0.9 is the B-phase output for axis 5, and Y0.11 is the B-phase output for axis 6.  High-speed comparison and catch: The terminals can function as high-speed comparison output terminals.

Y0.0+, Y0.0-, Y0.1+, Y0.1-, Y0.2+, Y0.2-, Y0.3+, Y0.3-, Y0.4+, Y0.4-, Y0.5+, Y0.5-, Y0.6+, Y0.6-, Y0.7+, and Y0.7- 1. They are differential output terminals. 2. The function of the terminals:  Motion control:  The terminals are for axis 1~axis 4.  Y0.0+ and Y0.0- are the A-phase output terminals for axis 1. Y0.2+ and Y0.2- are the A-phase output terminals for axis 2. Y0.4+ and Y0.4- are the A-phase output terminals for axis 3. Y0.6+ and Y0.6- are the A-phase output terminals for axis 4.  Y0.1+ and Y0.1- are the B-phase output terminals for axis 1. Y0.3+ and Y0.3- are the B-phase output terminals for axis 2. Y0.5+ and Y0.5- are the B-phase output terminals for axis 3.

Y0.7+ and Y0.7- are the B-phase output terminals for axis 4.  Y0.0+ and Y0.0- are the CLEAR output terminals for axis 5. Y0.1+ and Y0.1- are the CLEAR output terminals for axis 6. 1 MHz 5 mA 5 V Item AH15PM-5A Number of actual axes 4 axes Storage The capacity of the built-in storage is 64K steps. Unit Motor unit Compound unit Mechanical unit Users can set the initial register involved in the data exchange in a CPU Connection with a CPU module, and the number of registers involved in the data exchange in the module CPU module. Four hundred data registers at most can be involved in the data exchange. There are three types of pulse output modes. These modes adopt the differential output.

Motor control 1. Pulse/Direction 2. Counting up/Counting down 3. A/B-phase output Single axis: 1M PPS Maximum speed Multi-axis interpolation: 1M PPS Operating STOP/RUN (automatic/manual switch) switch Input signal X0.0+, X0.0-, X0.1+, X0.1-, X0.2+, X0.2-, X0.3+, and X0.3-, X0.4, X0.5, Detector X0.6, X0.7, X0.10, X0.11, X0.12, X0.13, X0.14, X0.15, X1.0, X1.1, X1.2, X1.3, X1.4, X1.5 Servo output Y0.0+, Y0.0-, Y0.2+, Y0.2-, Y0.4+, Y0.4-, Y0.6+, Y0.6-, Y0.1+, Y0.1-, Output signal signal Y0.3+, Y0.3-, Y0.5+, Y0.5-, Y0.7+, Y0.7-, Y0.8, Y0.9, Y0.10, and Y0.11