Chapter 10 DeviceNet Communication Module AH10DNET Note: If “E7” is displayed on AH10DNET-5A, please remove its DeviceNet terminals before downloading. Otherwise, failure to download will occur. 11. Power off the AH500 series CPU module and then power it on again after downloading is finished. And at the time, AH10DNET-5A is set to the master mode. 10.7.2 Mapping Areas Setting When AH10DNET-5A serves as a master, there are two methods of modifying the starting address of its mapping areas. Method 1: Modifying the starting address of the mapping areas through ISPSoft and DeviceNet Builder 1.
PC accesses an AH500 series CPU module via USB after connecting the device according to the following figure. 10-23 PS05 DeviceNet Builder CPU530-EN AH10DNET-5A P S05 C PU530-EN 10DNET RS232 Note: The introduction in this section is made in the USB communication method. 2. Open ISPSoft, select “File” >> “New” >> “New” and then the following dialog box appears where select the corresponding PLC. Note: The PLC used in this section is AHCPU530-EN. PS05 CPU530-EN AH10DNET-5A P S05 C PU530- EN 10DNET made in > “New” HCPU5 the U and th 30-EN SB commun en the follow . ication method. ing dialog box appears where