AH500 Module Manual Model of Delta PROFIBUS DP slaves and function description 12.4.3 Notes on Network Wiring Please see the following notes on the PROFIBUS DP network wiring. Select the standard PROFIBUS communication cable The two ends of the PROFIBUS cable must connect the terminal resistors respectively For connecting the PROFIBUS cable into the connector, remove the shielded layer and squeeze the metal part inside the connector The power wire of high voltage and strong current uses the wire casing different from that of low voltage and weak current for wiring.
DO NOT install the network cable too near to the power wire and DO NOT wrap them together and keep the PROFIBUS DP network cable away from I/O module cable The bus cable and power cable should avoid long-distance parallel wiring Put the bus cable as near as possible to the metal plate. Reduce the impact on the devices from the interference source such as the AC motor drive. For example, ground the shielded wire in the power cable of the AC motor drive or adopt the filtering method via the ferrite bead.
12-12 Product Model Description AH10PFBS-5A AH10PFBS-5A is a PROFIBUS DP slave module running on the I/O slot of AH main rack and used to connect the AH series PLC CPU to the PROFIBUS DP network. AHRTU-PFBS-5A AHRTU-PFBS-5A is a PROFIBUS DP remote I/O communication module and used to connect Delta AH series I/O module to the PROFIBUS DP network. DVPPF02-SL DVPPF02-SL is a PROFIBUS DP slave module running on the left side of the S series and EH2 series PLC CPU and used to connect the PLC CPU to the PROFIBUS DP network. The PLC CPU the left side of which could connect DVPPF02-SL can be DVP-28SV, DVP- 28SV2, DVP-SX2, DVP-SA2 and DVP-EH2-L.
DVPPF02-H2 DVPPF02-H2 a PROFIBUS DP slave module running on the right side of the EH2 series PLC CPU and used to connect the PLC CPU to the PROFIBUS DP network. RTU-PD01 RTU-PD01, a PROFIBUS DP remote I/O module is used to connect the S series digital, analog and standard MODBUS (with the RS-485 interface) device to the PROFIBUS DP network. The RS-485 interface can connect 16 MODBUS devices at most. DVPPF01-S DVPPF01-S, a PROFIBUS DP slave module, is used to connect Delta SS2/SV/SV2/SX2/SA2 series PLC CPU to the PROFIBUS DP network. CMC-PD01 CMC-PD01, a PROFIBUS DP slave card, is used to connect the C2000 series AC motor drive to the PROFIBUS DP network.
PD-01 PD-01 is a gateway transforming the PROFIBUS to MODBUS and is used to connect the device with the RS-485 interface (Conforming to the MODBUS protocol) to the PROFIBUS DP network.