AH500 Motion Control Module Manual S : Source device; D : Destination device The number of bits which are 1 in S is stored in D . If the bits in S are 0, a zero flag will be ON. If the 32-bit instruction is used, D will occupy two registers. If KnM/KnS is used, it is suggested that M device numbers/S device numbers should start from a number which is a multiple of 16 in the decimal numeral system, e.g. K1M0 and K4M16 (decimal numeral system). SM1064 is the zero flag in an Ox motion subroutine, and SM968 is the zero flag in O100. Explanation When X2.0 is ON, the number of bits which are 1 in D0 is stored in D2.
Example X2.0 SUM 3 D2 D0 5-64 API Instruction code Operand Function 43 D SUM P S,D Number of bits which are ON Device Xn.n Yn.n M S K 16# F KnM KnS D W T C V Z S D Pulse instruction 16-bit instruction (5 steps) 32-bit instruction (5 steps ) D0 D2 0 0 0 1 0 0 1 0 0 0 0 0 0 1 0 0