Mitsubishi — 5.6 Descriptions of the Applied Instructions

AH500 Motion Control Module Manual Explanation  S : Source device; D : Conversion result  The instruction is used to convert a binary integer into a binary floating-point value. 1. If the absolute value of the converesion result is greater than the maximum floating-point value avaliable, a carry flag will be ON. 2. If absolute value of the conversion result is less than the mimum floating-point vlaue available, a borrow flag will be ON. 3. If the conversion result is 0, a zero flag will be ON.  SM1064 is the zero flag in an Ox motion subroutine, and SM968 is the zero flag in O100.  SM1065 is the borrow flag in an Ox motion subroutine, and SM969 is the borrow flag in O100.

 SM1066 is the carry flag in an Ox motion subroutine, and SM970 is the carry flag in O100.  When X1.1 is ON, the binary integer in (D1, D0) is converted into a binary floating-point value, and the conversion result is stored in (D21, D20).  Suppose the value in the 32-bit register (D1, D0) is K100,000. When X1.1 is ON, K100,000 is converted into the 32-bit floating-point number 16#4735000, and 16#4735000 is stored in the 32-bit register (D21, D20).

Example X1.1 5-70 API Instruction code Operand Function Converting a binary integer 49 D FLT P S, D into a binary floating-point value Device Xn.n Yn.n M S K 16# F KnM KnS D W T C V Z S     D   Pulse instruction 16-bit instruction 32-bit instruction (6 steps )  –  DFLT D0 D20