Mitsubishi — 5.6 Descriptions of the Applied Instructions

Chapter 5 Applied Instructions  m 1 : Special module number ( m 1 is in the range of 0 to 255.); m 2 : Control register number ( m 2 is in the range of 0 to 499.); D : Device in which the data read will be stored; n : Quantity of data which will be read (16-bit instruction: 1~(500- m 2 ); 32-bit instruction: 1~(500- m 2 )/2  A motion control module can read the data in a control register in a special module by means of the instruction. Explanation  The value in CR#29 in special module 0 is read, and then stored in D0 in the motion control module. The value in CR#30 in special module 0 is read, and then stored in D1 in the motion control module. The two values are read at the same time.

 When X0.0 is ON, the instruciton is executed. When X0.0 is turned OFF, the instruction is not executed, and the values which are read remain unchanged. Example X0.0 5-75 API Instruction code Operand Function Reading data from a 78 D FROM P m , m , D, n 1 2 control register in a special module Device Xn.n Yn.n M S K 16# F KnM KnS D W T C V Z m 1         m 2         D     n         Pulse instruction 16-bit instruction (9 steps ) 32-bit instruction (12 steps )    FROM K0 K29 D0 K2