AH500 Motion Control Module Manual Explanation S : Source value (binary floating-point value); D : Hyperbolic sine value Hyperbolic sine value=(e s -e -s )/2 When X0.0 is ON, the hyperbolic sine of the binary floating-point number in (D1, D0) is stored in (D11, D10). Example X0.0 Binary floating-point value S If the absolute value of a conversion result is greater than the maximum floating-point value available, a carry flag will be ON. If the absolute value of a conversion reuslt is less than the minimum floating-point value available, a borrow flag will be ON. If a converseion result is 0, a zero flag will be ON.
SM1064 is the zero flag in an Ox motion subroutine, and SM968 is the zero flag in O100. SM1065 is the borrow flag in an Ox motion subroutine, and SM969 is the borrow flag in O100. SM1066 is the carry flag in an Ox motion subroutine, and SM970 is the carry flag in O100. D Hyperbolic sine value Binary floating-point value Additional remark Please refer to section 5.3 for more information about performing operations on floating-point numbers.
5-102 API Instruction code Operand Function Hyperbolic sine of a 136 D SINH P S, D binary floating-point number Device Xn.n Yn.n M S K 16# F KnM KnS D W T C V Z S D Pulse instruction 16-bit instruction 32-bit instruction (6 steps ) – DSINH D0 D10 D 1 D 0 D 11 D 10