Chapter 5 Applied Instructions 5.9 Delta-defined Parameter Table Delta-defined parameters are for input pins in Delta motion control function blocks. Users can directly use Delta-defined parameters to operate motion control function blocks without having to know the descriptions of the input pins in the motion control function blocks. Delta-defined parameters are described below.
5-135 Name Type Value Motion control function block Description TRUE BOOL True All motion control function blocks Input pin FALSE BOOL False Input pin mcRising BOOL True T TrSeg2, T TrSeg1, _ _ T HomeReturn _ Transition in DOG’s signal from low to high mcFalling BOOL False Transition in DOG’s signal from high to low mcPositive BOOL True T HomeReturn _ Returning home in the positive direction mcNegative BOOL False Returning home in the negative direction mcSCurve BOOL True T AxisSetting2 _ Speed curve: S curve mcTrapezoid BOOL False Speed curve:
Trapezoid curve mcNC BOOL True T InputPolatiry _ Normally-closed contact mcNO BOOL False Normally-open contact mc32bits BOOL True T DMCServoWrite _ 32-bit value mc16bits BOOL False 16-bit value mcUp Up _ BOOL True T HTmr _ A high-speed timer becomes active when its signal goes from low to high. mcUp Down _ BOOL False A high-speed timer becomes active when its signal goes from high to low. mcCmpSet BOOL True T Compare _ An output is set when the condition of a comparison is met. mcCmpRst BOOL False An output is reset when the condition of a comparison is met.
mcMotor WORD 0 T AxisSetting2 _ Motor unit mcMachine WORD 1 Mechanical unit mcComp WORD 2 Compound unit mcUD WORD 0 T AxisSetting2, _ T HCnt _ Counting up/down mcPD WORD 1 Pulses+Directions mcAB WORD 2 A/B-phase pulses mc4AB WORD 3 Four times the frequency of A/B-phase pulses mcSD M _ WORD 0 T SDDevRead _ Using M devices mcSD D _ WORD 5 Using D devices mcSD W _ WORD 6 Using W devices