Mitsubishi — 5.10.1 Absolute Single-speed Motion

AH500 Motion Control Module Manual 5.10 Uniaxial Motion Control Function Blocks 5.10.1 Absolute Single-speed Motion 1. Motion control function block The motion control function block T_AbsSeg1 is used to start absolute single-speed motion. The value of the Axis input pin indicates an axis number, and the value of the Velocity input pin indicates the speed of single-speed motion. The value of the Position input pin indicates the target position of single-speed motion, and the target position is an absolute position. 2.

Input pins/Output pins 5-138 Input pin Name Function Data Setting value Time when a value is valid type Axis Motion axis number WORD K1~K16 The value of the Axis input pin is valid when there is a transition in the Execute input pin’s signal from low to high. Execute Motion is started when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False - Position Absolute position DWORD K-2,147,483,648~ K2,147,483,647 The value of the Position input pin is valid when there is a transition in the Execute input pin’s signal from low to high.

Velocity Target speed DWORD K1~K2,147,483,647 When the motion control function block is executed, the value of the Velocity input pin is updated repeatedly. Output pin Name Function Data type T ime when there is a Time when there is a transition in an output pin’s signal from high to low transition in an output pin’s signal from low to high Done The execution of the motion control function block is complete. BOOL  There is a transition in the Done output pin’s signal when motion is complete.  There is a transition in the Done output pin’s signal from high to low when there is a transition in the Execute input pin’s signal from high to low.

 If the Execute input pin is set to False when motion is complete, the Done output pin will be set to False in the next cycle.