Chapter 5 Applied Instructions an output type, and a unit. The setting of a unit requires the number of pulses it takes for a motor to rotate once and the distance for which the axis specified moves when the motor rotates once. 2. Input pins/Output pins 5-177 Input pin Name Function Data Setting value Time when a value is valid type Axis Motion axis number WORD K1~K16 The value of the Axis input pin is valid when there is a transition in the Execute input pin’s signal from low to high. Execute Parameters are written when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False - Vcurve Velocity curve BOOL mcTrapezoid: False mcSCurve:
True The value of the Vcurve input pin is valid when there is a transition in the Execute input pin’s signal from low to high. OutputType (AH20MC-5A is not supported.) Output type WORD mcUD: 0 mcPD: 1 mcAB: 2 mc4AB: 3 The value of the OutputType input pin is valid when there is a transition in the Execute input pin’s signal from low to high. Unit Unit WORD mcMotor: 0 mcMachine: 1 mcComp: 2 The value of the Unit input pin is valid when there is a transition in the Execute input pin’s signal from low to high.
PulseRev Number of pulses it takes for a motor to rotate once DWORD K1~K2,147,483,647 The value of the PulseRev input pin is valid when there is a transition in the Execute input pin’s signal from low to high. DistanceRev Distance for which the axis specified moves when the motor used rotates once DWORD K1~K2,147,483,647 The value of the DistanceRev input pin is valid when there is a transition in the Execute input pin’s signal from low to high.