Chapter 5 Applied Instructions 5.10.14 State of an Axis 1. Motion control function block The motion control function block is T_AxisStatus is used to read and clear the present erroneous state of an axis. The value of the Axis input pin indicates an axis number. Users can clear the present erroneous state of the axis specified by means of the ClearError input pin. The value of the AxisErrorID output pin indicates the present erroneous state of the axis specified. 2.
Input pins/Output pins 5-181 Input pin Name Function Data Setting value Time when a value is valid type Axis Motion axis number WORD K1~K16 The value of the Axis input pin is valid when there is a transition in the Enable input pin’s signal from low to high. Enable Enabling the displaying of the state of an axis BOOL True/False - ClearError The erroneous state of the axis specified is cleared when there is a transition in the ClearError input pin’s signal from low to high. BOOL True/False The value of the ClearError input pin is valid when the motion control function block is executed.