Mitsubishi — 5.10.18 Electronic Cam Motion

Chapter 5 Applied Instructions 2. Input pins/Output pins 5-191 Input pin Name Function Data Setting value Time when a value is valid type Master Master axis number WORD 0~16, 200, 204, 208, 212, 216, 220 (*1) The value of the Master input pin is valid when there is a transition in the Enable input pin’s signal from low to high. Slave Slave axis number WORD 1~16 The value of the Slave input pin is valid when there is a transition in the Enable input pin’s signal from low to high.

Enable Enabling electronic cam motion BOOL True/False - Reset Resetting the InputPulses output pin BOOL True/False The value of the Reset input pin is valid when there is a transition in the Enable input pin’s signal from low to high. CamOut Not meshing with the master axis specified BOOL True/False The value of the CamOut input pin is used when the motion control function block is executed. CycleStop Stopping a whole cycle BOOL True/False The value of the CycleStop input pin is valid when there is a transition in the Enable input pin’s signal from high to low. MasterOffset Starting angle of the axis specified (Unit:

Pulse) DWORD K0~ K2,147,483,647 The value of the MasterOffset input pin is valid when there is a transition in the Enable input pin’s signal from low to high. MasterScaling Ratio which is used to reduce/enlarge the number of pulses sent by the master axis specified FLOAT 0.~650.00 (two decimal places) The value of the MasterScaling input pin is valid when there is a transition in the Enable input pin’s signal from low to high. SlaveScaling Ratio which is used to reduce/enlarge the number of pulses sent by the slave axis specified FLOAT 0.~650.00 (two decimal places) The value of the SlaveScaling input pin is valid when there is a transition in the Enable input pin’s signal from low to high.