Chapter 5 Applied Instructions *1: Value of the Source input pin 3. Troubleshooting 4. Modules which are supported The motion control function block T_DMCCapSet supports AH20MC-5A. 5.12.8 Setting an Ethernet IP Address 1. Motion control function block The motion control function block T_TcpIPAddr is used to set the Ethernet IP address of the module used. Users can set an IP address by means of the IPv4_1 input pin, the IPv4_2 input pin, the IPv4_3 input pin, and the IPv4_4 input pin. 2. Input pins/Output pins 5-237 Value Definition 0 Invalid 1 Auxiliary encoder 2 Pulse command 3 Main encoder Error Troubleshooting The values of input pins in the motion control function block are incorrect.
Check whether the values of the input pins are in the ranges allowed. Input pin Name Function Data Setting value Time when a value is valid type Execute The values of parameters are written when there is a transition in the Execute input pin’s signal from low to high. BOOL True/False - IPv4 1 _ First byte of an IP address WORD K0~255 The value of the IPv4 1 _ input pin is valid when there is a transition in the Execute input pin’s signal from low to high. IPv4 2 _ Second byte of an IP address WORD K0~255 The value of the IPv4 2 _ input pin is valid when there is a transition in the Execute input pin’s signal from low to high.
IPv4 3 _ Third byte of an IP address WORD K0~255 The value of the IPv4 3 _ input pin is valid when there is a transition in the Execute input pin’s signal from low to high.