Mitsubishi — 6.3 Usage

Chapter 6 Data Transmission Click in the Setup cell for AHCPU>>AH20MC-AHCPU D (M) Device Start Number . In the Address window, type 5400 in the CPU Module Address box, type 3400 in the IO Module Address box, and type 400 in the Length box. Click OK in the Address window. 4. Program created in PMSoft After AH20MC-5A exchanging values with the AH500 series CPU module, it can write the values gotten from the AH500 series CPU module into SR registers by means of a program created in PMSoft. The program below is about single-speed motion. The values in D3401 and D3402 are written into SR1023 and SR1024. The values in SR1023 and SR1024 indicate the target position of the first axis.

The value in D3403 is written into SR1030. The value in SR1030 indicates an operation command. Besides, the value in D3000 is determined by the state of SM1048. The AH500 series CPU module can judge whether the single-speed motion is complete by means of the value in D3000. 6-7