AH500 Motion Control Module Manual 11.5 Masking A value can be masked in a high-speed capture mode. If the relative difference between the value captured this time and the value captured last time is in the range which can be masked, the signal which triggers the capture of the value this time will be disregarded. Setting X0.0 Module number Control register number Initial device number Number of values N=4 Definitions After masking is started, it will be applied to eight values captured. 11-14 FROM K253 K1 S N Device Setting S 0 S +1 2 (S , S ) +3 +2 Value indicating the range which is masked