Delta Electronics AH500 — 2.8.1 General Specifications

Chapter 2 Specifications and System Configuratio n Description of the terminals 2-82 Terminal Description c Response c Maximum input haracteristi Curren t Voltage X0.0+, X0.0-, X0.1+, X0.1-, X0.2+, X0.2-, X0.3+, and X0.3- 1. They are differential input terminals. 2. The functions of the terminals:  High-speed count:  The terminals are the RESET input terminals for counter 0~counter 5.  X0.0+ and X0.0- are for counter 0. X0.1+ and X0.1- are for counter 1. X0.2+ and X0.2- are for counter 2 and counter 4. X0.3+ and X0.3- are for counter 3 and counter 5.  High-speed comparison and catch: The terminals can function as trigger signals for high-speed catches.

200 kHz 15 mA 5~24 V X0.8+, X0.8-, X0.9+, and X0.9- 1. They are differential input terminals. 2. The functions of the terminals:  Motion control: The terminals are for a manual pulse generator.  High-speed count:  The terminals are for counter 0.  X0.8+ and X0.8- are the A-phase input terminals for counter 0. X0.9+ and X0.9- are the B-phase input terminals for counter 0.  High-speed comparison and catch: The terminals can function as trigger signals for high-speed catches.  Interrupt input terminals 200 kHz 15 mA 5~24 V X0.10+, X0.10-, X0.11+, X0.11-, X0.12+, X0.12-, X0.13+, X0.13, X0.14+, X0.14-, X0.15+, and X0.15- 1. They are differential input terminals. 2.

The functions of the terminals:  Motion control: Dog inputs are for Axis1~Axis 6 and for the motion of the single-axis inputting.  High-speed count:  The terminals are for counter 1~counter 5.  X0.10+ and X0.10- are the A-phase input terminals for counter 1. X0.12+ and X0.12- are the A-phase input terminals for counter 2 and counter 4. X0.14+ and X0.14- are the A-phase input terminals for counter 3 and counter 5.  X0.11+ and X0.11- are the B-phase input terminals for counter 1. X0.13+ and X0.13- are the B-phase input terminals for counter 2 and counter 4. X0.15+ and X0.15- are the B-phase input terminals for counter 3 and counter 5.  High-speed comparison and catch:

The terminals can function as trigger signals for high-speed catches.  Interrupt input terminals 200 kHz 15 mA 5~24 V