Chapter 9 Network Configuration After the users follow the steps described above, the Optional Download window will appear. If a checkbox in the Optional Download window is gray, the checkbox can not be selected. After the users select checkboxes in the Optional Download window, they can click OK .

9.3.3 Using Routing in ISPSoft After users create a network architecture in NWCONFIG, and download the routing tables produced to PLCs, they can download data to a device which is not directly connected to ISPSoft through routing, upload data from a device which is not directly connected to ISPSoft through routing, or monitor data in a device which is not directly connected to ISPSoft through routing. If the users want to use routing in ISPSoft, the devices used must be AH500 series CPU modules. In the figure below, the PLC which actually connects to the computer is AH-01. AH-03 can be monitored through routing. (1) Users have to activate the project for AH-03. 9-39